18ÐÂÀû

²úƷͼƬ²úÆ·¼ò½éÒªº¦ÌØÕ÷ÐÔÄܲÎÊý»úе³ß´ç¶©¹ºÐÅÏ¢×ÊÁÏÏÂÔØ
·¢ËÍѯÅÌ
SICOM3024P
28G¶Ë¿Ú¶þ²ãȫǧÕ×Íø¹ÜÐÍ»ú¼Üʽ½»Á÷»ú
²úÆ·¼ò½é

SICOM3024PÊÇÕë¶ÔEMCÐÔÄÜÒªÇóÑÏ¿áµÄ¹¤ÒµÍ¨Ñ¶ÏµÍ³ÐèÇóÉè¼ÆµÄ¶þ²ãÍø¹ÜÐ͹¤ÒµÒÔÌ«Íø½»Á÷»ú£¬£¬£¬£¬£¬£¬×î¸ßÖ§³Ö28 ¸öǧÕ×½Ó¿Ú£¬£¬£¬£¬£¬£¬²¢¿ÉÑ¡Bypass ¹¦Ð§¡£¡£¡£¡£¡£ ¡£¡£ ¡£SICOM3024P½»Á÷»úΪ19Ó¢´ç»ú¼ÜʽװÖ㬣¬£¬£¬£¬£¬²úÆ·Ö§³ÖDT-Ring ЭÒé×壨×ÔÓúʱ¼ä<50ms£©£¬£¬£¬£¬£¬£¬DRP/DHP£¨×ÔÓúʱ¼ä<20ms£©£¬£¬£¬£¬£¬£¬MSTP/RSTP/ STP£¬£¬£¬£¬£¬£¬VLAN£¬£¬£¬£¬£¬£¬×é²¥£¬£¬£¬£¬£¬£¬QoS µÈ¸»ºñµÄ¶þ²ãÈí¼þÌØÕ÷£»£» £»£»£»£»£»£»ÒÔ¼°·À¹¥»÷¡¢DHCP snooping¡¢IP source guard¡¢SSH¡¢SFTP¡¢802.1x¡¢AAA ÈÏÖ¤¡¢Óû§È¨ÏÞ·Ö¼¶¡¢¸ß¼¶ÃÜÂë¹ÜÀíµÈÇå¾²ÌØÐÍ£»£» £»£»£»£»£»£»²¢Ö§³ÖCLI£¬£¬£¬£¬£¬£¬Telnet£¬£¬£¬£¬£¬£¬Web ÒÔ¼°»ùÓÚSNMPv1/v2c/v3 µÄÍøÂç¹ÜÀí¡£¡£¡£¡£¡£ ¡£¡£ ¡£ÏÖÔÚÒѾ­ÆÕ±éÓ¦ÓÃÔÚµçÁ¦¡¢¹ì½»½»Í¨¡¢Ê¯ÓÍ»¯¹¤¼°ÆäËû¶ÔEMCÐÔÄÜÓÐÑÏ¿áÒªÇóµÄ¹¤ÒµÍ¨Ñ¶ÏµÍ³ÖС£¡£¡£¡£¡£ ¡£¡£ ¡£

Òªº¦ÌØÕ÷

×î´óÖ§³Ö28 ¸öǧÕ×ÒÔÌ«Íø½Ó¿Ú
Ö§³ÖBypass½Ó¿Ú£¨¿ÉÑ¡£¡£¡£¡£¡£ ¡£¡£ ¡£©
Ö§³ÖDRP¡¢DT-Ring¼°RSTP/MSTP¡¢ERPSµÈ¶àÖÖÈßÓà×éÍø»úÖÆ
Ö§³ÖHTTPS/SSL, SSH, TACACS+, IEEE802.1X, RADIUS,Óû§·Ö¼¶µÈ¶àÖÖÇå¾²»úÖÆ
Ö§³Ö»ùÓÚÓ²¼þµÄPTP¹¦Ð§£¬£¬£¬£¬£¬£¬Ê±ÖÓͬ²½¾«¶È¿É´ï±100ns
Ö§³Ö¸»ºñµÄ¹ÊÕÏÕï¶ÏÓëÊÂÎñ¸æ¾¯¹¦Ð§

ÐÔÄܲÎÊý
Èí¼þ¹¦Ð§
½»Á÷¹¦Ð§ Ö§³ÖVLAN
Ö§³ÖQinQ
Ö§³ÖÁ´Â·¾ÛºÏ
Ö§³ÖËÙÂÊË«¹¤ÉèÖÃ
Ö§³ÖÒì³£Ö¡¼ì²â
Ö§³ÖÁ÷Á¿¿ØÖÆ
Ö§³Ö³¬³¤Ö¡×ª·¢
Ö§³Ö·ç±©ÒÖÖÆ¹¦Ð§
ÈßÓàÊÖÒÕ Ö§³Ö»ùÓÚIEC62439-6±ê×¼µÄDRP/DHP, ×ÔÓúʱ¼ä<20ms
Ö§³ÖDT-Ring, DT-Ring+, DT-VLAN ЭÒé×å, ×ÔÓúʱ¼ä<50ms
Ö§³ÖRSTP/MSTP, ¼æÈÝSTP
Ö§³ÖERPS
×é²¥ÊÖÒÕ Ö§³ÖIGMP Snooping
Ö§³Ö¾²Ì¬×é²¥
·þÎñÖÊÁ¿¹ÜÀí Ö§³ÖACL, ¶ÔL2-L4 ²ãÊý¾Ý¾ÙÐйýÂË
Ö§³ÖSP,WRR ÐÐÁе÷Àí
Ö§³Ö802.1p(CoS),DSCP
Ö§³ÖÏÞËÙ
Çå¾²¹¦Ð§ Ö§³Ö±¨ÎĹýÂË
Ö§³Ö·À¹¥»÷
Ö§³ÖCPU ±£»£» £»£»£»£»£»£»¤
Ö§³ÖDHCP snooping
Ö§³ÖIP source guard
Ö§³ÖSFTP
Ö§³ÖSSH
Ö§³Ö¸ß¼¶ÃÜÂë¹ÜÀí
Ö§³Ö802.1x
Ö§³ÖÍâµØÈÏÖ¤£¬£¬£¬£¬£¬£¬RADIUS ÈÏÖ¤
Ö§³ÖÓû§È¨ÏÞ·Ö¼¶
Ö§³ÖÇå¾²¹ÜÀíIP
Ö§³Ö¶Ë¿Ú,IP,MAC °ó¶¨
Ö§³Ö¶Ë¿Ú°ÎÏß×Ô¶¯¹Ø±Õ
¹ÜÀíÓëά»¤ Ö§³ÖÏÂÁîÐÐ, WEB ¹ÜÀí·½·¨
Ö§³ÖSNMPv1/v2c/v3£¬£¬£¬£¬£¬£¬¿Éͨ¹ýKyvision ¼¯ÖйÜÀí
Ö§³ÖÈí¼þÉý¼¶
Ö§³ÖÉèÖÃÎļþÉÏ´«ÏÂÔØ
Ö§³Ö×Ô¶¯ÏÂÔØÉèÖÃ
Ö§³ÖµçÔ´¸æ¾¯, ζȸ澯£¬£¬£¬£¬£¬£¬IP/MAC ³åÍ»¸æ¾¯, ÄÚ´æ/CPU ʹÓÃÂʸ澯, ¶Ë¿Ú¸æ¾¯,»·¸æ¾¯, ¶Ë¿ÚÁ÷Á¿¸æ¾¯, CRC ¼°¶ª°üÂʸ澯, SFP ½Ó¿ÚÎüÊÕ¹â
¹¦Âʸ澯ºÍ·¢Ë͹⹦Âʸ澯
Ö§³ÖUDLD ÅþÁ¬¼à²â
Ö§³ÖLLDP
Ö§³ÖRMON
Ö§³ÖSyslog
Ö§³ÖDDM (SFP ½Ó¿Ú)
Ö§³Ö¶Ë¿Ú¾µÏñ
ʱÖÓ¹ÜÀí Ö§³ÖNTP
Ö§³ÖPTPv2
²úÆ·¹æ¸ñ
ÊÖÒÕ²ÎÊý ±ê×¼
IEEE 802.3i (10Base-T)
IEEE 802.3u (100Base-T and 100Base-FX)
IEEE 802.3ab (1000Base-T)
IEEE 802.3z (1000Base-SX/LX)
IEEE 802.3ad (Á´Â·¾ÛºÏ)
IEEE 802.3x (Á÷¿Ø)
IEEE 802.1p (ÓÅÏȼ¶)
IEEE 802.1Q (VLAN)
IEEE 802.1d (STP)
IEEE 802.1w (RSTP)
IEEE 802.1s (MSTP)
IEEE 802.1x (Network Access Control)
IEEE 802.1ab (LLDP)
½»Á÷ÊôÐÔ ÓÅÏȼ¶ÐÐÁÐ 8
VLANÊý 4K
MAC±í 16K
ACL 512
½»Á÷ÈÝÁ¿ 56Gbps
°üת·¢ÂÊ 83.3Mpps
½»Á÷ÑÓ³Ù <10¦Ìs
ʱÑÓ²ü¶¶ <1¦Ìs
½Ó¿Ú ǧÕ×¶Ë¿Ú 10/100/1000Base-T(X) RJ45 µç¿Ú,100Base-X,1000Base-X, SFP ½Ó¿Ú
Console¿Ú RS232,RJ45 ½Ó¿Ú
¸æ¾¯¶Ë¿Ú 3о5.08mm ¼ä¾à²åÈëʽ¶Ë×Ó,250VAC/220VDC Max,2A Max, 60W Max
ָʾµÆ ºóÃæ°åָʾµÆ
ÔËÐÐָʾµÆ£ºRun
¸æ¾¯Ö¸Ê¾µÆ£ºAlarm
µçԴָʾµÆ£ºPWR1£¬£¬£¬£¬£¬£¬PWR2
½Ó¿ÚָʾµÆ£ºLink/ACT
µçÔ´ ÊäÈëµçѹ 100-240VAC,50/60Hz;110-220VDC£¬£¬£¬£¬£¬£¬24-48VDC£»£» £»£»£»£»£»£»Îó²î¡À20%
½ÓÈë¶Ë×Ó 5о5.08mm¼ä¾à²åÈëʽ¶Ë×Ó
¹¦ÂÊ <40W
¹ýÔØ±£»£» £»£»£»£»£»£»¤ Ö§³Ö
·´½Ó±£»£» £»£»£»£»£»£»¤ Ö§³Ö
ÈßÓà±£»£» £»£»£»£»£»£»¤ Ö§³Ö
»úе½á¹¹ Íâ¿Ç ½ðÊô²ÄÖÊ
É¢ÈÈ·½·¨ ×ÔÈ»ÀäÈ´£¬£¬£¬£¬£¬£¬ÎÞµçÉÈ
·À»¤Æ·¼¶ IP40
³ß´ç 440mm¡Á44mm¡Á197.4mm(W¡ÁH¡ÁD)
ÖØÁ¿ <3Kg
×°Ö÷½·¨ 19Ó¢´ç1U»ú¼Üʽ
ÇéÐÎ ÊÂÇéÎÂ¶È -40¡æ¡« +75¡æ
Öü´æÎÂ¶È -40¡æ¡« +85¡æ
Ïà¶Ôʪ¶È 5-95% ÎÞÄý¶
Öʱ£ MTBF >200000h
±£ÐÞÆÚ 5Äê
ÐÐÒµ±ê×¼ EMI
FCC CFR47 Part 15£¬£¬£¬£¬£¬£¬EN55032/CISPR22£¬£¬£¬£¬£¬£¬Class A
EMS
IEC61000-4-2(ESD) ¡À6kV(contact),¡À8kV(air)
IEC61000-4-3(RS) 10V/m(80MHz-1GHz)
IEC61000-4-4(EFT) Power Port:¡À2kV;Data Port:¡À1kV
IEC61000-4-5(Surge) Power Port:¡À1kV/DM,¡À2kV/CM;Data Port:¡À2kV
IEC61000-4-6(CS) 3V(10kHz-150kHz)£»£» £»£»£»£»£»£»10V(150kHz-80MHz)
IEC61000-4-8( ¹¤Æµ´Å³¡) 100A/m(cont.)£¬£¬£¬£¬£¬£¬1000A/m(1s-3s)
IEC61000-4-9( Âö³å´Å³¡) 1000A/m
»úе
IEC60068-2-6( Õñ¶¯)
IEC60068-2-27( ¹¥»÷)
IEC60068-2-32( ×ÔÓɵøÂä)
»úе³ß´ç

18ÐÂÀûluck¡¤(Öйú)-¹Ù·½ÍøÕ¾

¶©¹ºÐÅÏ¢

ÍÆ¼öÐͺŠ

²úÆ·ÐͺŠǧÕ×¹âµç¸´ÓÃ¿Ú Ç§Õ×¹â¿Ú ǧÕ×µ¥Ä£Bypass¹â¿Ú ǧÕ×µç¿Ú ¸ßѹ¹©µç
SICOM3024P-4GX24GE-HV-HV   4   24 2·
SICOM3024P-8G12GX8GE-HV-HV 8 12   8 2·
SICOM3024P-8G8GX4GBS8GE-HV-HV 8 8 4 8 2·

 

×ÊÁÏÏÂÔØ
ÍøÕ¾µØÍ¼